Ni pxi-8335. Any action against National Instruments must be brought within one year after the cause of action accrues. Ni pxi-8335

 
 Any action against National Instruments must be brought within one year after the cause of action accruesNi pxi-8335 Summary of Contents for National Instruments PXI Express PXIe-1073

Note If you are running Windows 8, you may not have a Start menu. National Instruments PXI-8335. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 3221366881@qq. Hi everyone, I am currently using two NI PXI-2575 196-channels multiplexers and I have a crosstalk issue. National Instruments. Condition. The PCI version fits in a PCI slot inside a regular desktop PC. Select the NI PXI-6682 (H) or NI PXI-6683 (H) in your chassis and select the Test Panels button. Download the product flyer to learn more about the specifications, benefits, and applications of NI PXI Switch Modules. Fax: (240) 376-1381. NOTE TO USERS MXI Express Series User Manual The MXI Express Series User Manual has not been included on the CD shipped with your kit. Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. This interface is compatible with x1, x4, x8, and x16 PCI Express slots, so you. In this case I suspect that one of the 8335 boards (or cable) is broken. NI-488. NI PXI Express embedded controllers are compatible with a variety of PXI and PXI Express chassis and modules, and provide reliable and flexible solutions for. Kit includes: 186943B-03: CCA PCI-8330 Fast Reset Card 186897D-01: CCA PXI-8330 Card 1324640-4 0332: 1. Find many great new & used options and get the best deals for NATIONAL INSTRUMENTS NI PXI-8105 EMBEDDED CONTROLLER MODULE at the best online prices at eBay! Free shipping for many products!This section contains general installation instructions for the NI PXIe-8135. Add to Wish List Add to Compare. 7 GHz Intel i5-4400E CPU. Thousands of model numbers in stock. NI-488. I try to initialize my PXI-1000 chassis, with a PCI-MXI-3. ({{ cartItems. Part Number: 188535B-01, 188535C-01, 188535D-01,188535E-01, 188535F-01, 778955-01, 188537B-01. Ł EULAs are located in the <National Instruments>SharedMDFLegallicense directory. NI-RFSG provides support for customers using NI PXI RF Analog Signal Generators, PXI Vector Signal Generators, and the RF outputs of the PXI Vector Signal Transceiver. Manufacturer: National Instruments Model: PXI-8335 PXI-8335, Fiber-optic Cable, MXI-3 Interface Module National Instruments PXI-8335 Interface ModuleThe National Instruments PXI-8335 (Part Number: 777947-01) is an Interface Module with MXI-3 technology. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. PXIe-8135 User Manual - NIThis document provides information about the PXIe-8135 , a high-performance embedded controller for PXI Express systems. ; Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For. View and Download National Instruments PXI-8335 user manual online. 06-25-2018 11:24 AM. Configuration: • Processor: Intel Core i7 2. . Find many great new & used options and get the best deals for National Instruments Bridge PXI-8335 MXi-3 and PCI-8330 PCie Card isolation at the best online prices at eBay! Free shipping for many products!ni-daqmx. 13. 修理、RMA、キャリブレーション予定. I have used the PXI system with PXI-1000b chassis for half a year and the last time is a week ago. The software is Labview 2010 sp1 and 380 NIScope. MXI-Express x1 is based on PCI Express technology, using PCI Express switches and/or bridges to enable control of a PXI or PXI Express chassis from a PC or laptop with an available PCI, PCI Express, or ExpressCard slot. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Find National Instruments, John Deere, AEMC, and Morrison for sale on Machinio. A valid service agreement may be required. The green LEDs PWR & LINK are lit while the orange LEDs RX & TX are off. Configuring through MAX. com | PXI Remote Control and System Expansion Table 1. . Consult your PXI Expre ss chassis user manual for specific instructions and warnings. Software The VXI-PXI834x and VXI-PCI834xRe: Ardence RTX VXI driver. Add to cart. 00. Re: PXIe 8360 not detected by MAX. Page 3 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 For further support information, refer to the Technical Support and Professional Services appendix. com today. If anyone knows where it might be lca. The PXIe-8135 includes two 10/100/1000BASE-TX (Gigabit) Ethernet ports, two SuperSpeed USB ports, and four Hi. If you don't see it, you probably wont get it. com today. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。The 8335 will not show up as a device itself and does not require a driver for base functionality. PXI-8335. 777947-01). Product Family. the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Review <National Instruments>\_Legal Information. 修理、RMA、キャリブレーション予定. 03-10-2010 04:29 PM. PXIe is a standard that leverages the. 421) 99. National Instruments PXI-8335 ; National Instruments PXI 8330 Series ; National Instruments Categories. National Instruments VME-MXI-2. Through MXI-Express technology, PXI Remote Control Modules provide a simple, transpar ent connection between the The National Instruments PXI-PCI8330 Series interface kits give PCs direct control of PXI/CompactPCI systems via a transparent hardware and software link, using MXI-3 technology. com | PXI Remote Control and System Expansion Figure 6. The PXI trigger bus naming can differ for some of the drivers when using the trigger configuration VI, for example, PXI_Trig0, TTL0, RTSI 0, but all of them refer to the same PXI trigger lines from 0 to 7. Add to Cart. MXI-3 Block Diagram. This interface couples to physically isolate buses with a copper data link capable (Sold. 2. From the user manual (page 39, "Software Installation and Configuration"):. 7 GHz Upconverter is used and in excellent condition. 1GB RAM. This unit ships in the National Instruments sealed static bag. Find National Instruments for sale on Machinio. PXI-5122, SCXI-1160, 778032-51, VCPX350153, PXI-6508, PXI-6527, PXI-8335, PXI-6711, PXI-8176, 183815-01. You can find the manual at:. Caution In some National Instruments chassis, such as the NI PXI-1042, you must ensure that the power LED is off. used. In the dialog box that appears, select GPS as the time reference and then. 4%Model: PXI-8335; National Instruments NI PXI-8335 MXI-3 Interface Module - Direct Trigger and Interrupt Control - Word Serial (Message-Based) Communication - Register-Based Communication. ZYOng. Table 1. NI 6535. 자세한 단계는 증상 1 : PXI (e) 섀시가 PCI (e) MXI 카드 에. NI-488. We offer repair services with a 1 week turnaround and calibration services with a 2 week turnaround. Per recommendation by NI rep few days back, we installed driver “PXI Platform services 15. NI PXI Waveform Generator Bundle. DC output characteristics of the PXIe-1083. com - Meet Superior Sourcing for NSN Parts. Lai Wechat:17750010683 Whats app:+86 17750010683Introduction This chapter describes the PXI-PCI 8330 Series, lists what you need to get started, and explains how to unpack and set up your hardware. NATIONAL INSTRUMENTS PXI-1045 CHASSIS & PXI-8186 CONTROLLER & PXI-8335 MXI-3. National Instruments PXI-8335 MXI-3 Interface Module. Wafer Size: Equipment Configuration: Equipment Pictures: Previous Next. After powering on the PCI side, your board should have the power and link light on (the link is established). Conventions The following conventions are used in. Abstract: PXI-PCI8330 PXI-8330 PCI-8330 MXI-3 8335 MXI3 10 8335 PXI-833x 8330 Series Text: No file text available Original: PDF PXI-PCI8330 PCI-8330 PXI-8330 PXI-8335 PCI-8335 MXI-3 8335 MXI3 10 8335 PXI-833x 8330 Series: 2007 - 192524-01. com. Introduction This chapter describes the PXI-PCI 8330 Series, lists what you need to get started, and explains how to unpack and set up your hardware. e. Trusted Seller. Figure 2-2 shows a PXI MXI-3 card just before installation in the system controller slot of a National Instruments PXI-1000 mainframe. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. I bought a PXI system years ago, controlled by a very old computer via a fiber optic link with a pci card. PXI-8335. National Instruments PCI-8335 MXI-3 Interface Module. PXI-2565-National Instruments . . ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. The same procedure applies for a. NI PXI remote control and system expansion offerings MXI-Express Technology Gen1 x1 Copper Gen1 x1 Fiber Optic Gen1 x4 Copper Gen1 x4 Fiber Optic Gen2 x8 Gen3 x4 Gen3 x16 Sustained Throughput1 100 MB/s (PXI-1) 100 MB/s 192 MB/s (PXI Express)MXI-Express BIOS Compatibility is utility software that helps you troubleshoot a connection between a PXI or PXI Express Chassis and your computer using MXI-Express. The PCI 8330 (Part number: 777944-01) is part of the MXI-3 innovation master/slave framework actualizing the PCI-PCI connect enroll set. The National Instruments VXI-PXI834x and VXI-PCI834x kits link any PXI system or PCI-based computer running Windows 2000/NT/Me/98 to the VXIbus using the high-speed MXI-3 interface. 2. National Instruments PCI-8335 MXI-3 Interface ModuleThis item has the optical fiber interface (not copper), as well as the dual heatsink configuration. NI PXI Switch Modules are high-performance switching solutions for automated test systems. At the moment these two chassis are connected by an MXI-3 system using PXI-8335 cards. comAsk for a quote on a Used National Instruments PXI-8335 Interfaces from Artisan Technology Group at used-line. National Instruments PXI-8335. The National Instruments PXI-PCI8330 Series interface kits give PCs direct control of PXI/CompactPCI systems via a transparent hardware and software link, using MXI-3 technology. Find National Instruments, AEMC, and Morrison for sale on Machinio. For example, by using an NI PXIe-1075 PXI Express chassis and an NI. For PXI modules, the NI PXIe-1078 backplane is fully compliant with PXI timing and synchronization standards. 62 + shipping. Part Number: 191435A-012, 191435E-012, 191435E-712, 191435E-722, 779911-33. Community. National Instruments PXI & VXI Boards & Modules, National Instruments Test, Measurement & Inspection Equipment,NI PXIe-8133. Trigger Configuration VIŁ Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories. Be the first to write a review. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 0 GHz Dual Core. PCI device – PCI\VEN1093&DEV…. Buy the National Instruments PXI-8335 from Direct. PXI Express chassis have a power supply that can be controlled by the PXI Express system controller. PXIe, 2. I want to use updated computers, and bought a PCI extension that I can use with laptops, but I cannot find the driver for the PCI card on the NI website. The PXIe‑6355 offers analog I/O, digital I/O, and four 32‑bit counter/timers for PWM, encoder, frequency, event counting, and more. Figure 8: NI has continued to deliver the latest and most powerful processing technology to the PXI platform for the last 20 years. National Instruments PXI-8196 2. The chassis contains the high-performance PXI backplane, which includes the PCI bus and timing and triggering buses. Click to enlarge. 8 m 787580-0R8 Connect the MXI-Express Thunderbolt cable to the host PC Thunderbolt port and PXIe-1083. The NI PXIe-8133 has one serial port, and an ECP/EPP parallel port. NI 6528/6529 The NI PCI/PXI-6528 device provides 24 isolated input channels and 24 isolated output channels, and the NI PXI-6529 provides 48 isolated input channels. To access NI 4080/4081/4082 documentation, navigate to Start»All Programs»National Instruments»NI-DMM Documentation. NI-DAQmx. Basic MXI-3 Configurations. This item was listed in the fixed price format with a Best Offer option. PXI-4461 4461. Everytime I run the MXI-3 optimization it says MXI-interface not detected. . Run the MXI BIOS Compatibility Software. Aerospace, Defense, & Government. It features high-performance DMA transfers, multithreading, and multiprocessor support. used. Each PXI Trigger Line, PXI_Trig0 through PXI_Trig7, can be configured under the Routing column to be one of four different options. Order by Part Number or Request a Quote. Manufacturer: National Instruments; Model: PXI; DC measurements - 20 mV to 250 VDC; 20 mA to 10 A AC measurements - 20 mVrms to 250 Vrms; 20 mArms to 10 Arms; true rms, 20 Hz to 25 kHz P-1 probe set, NI-DMM. PXIe, 80 AI (16-Bit, 1. Very good condition. 0) 3U modules. It features selectable. Options. Used National Instruments PXI-8335 general analytical equipment for sale in USA. Hi everyone, I am currently using two NI PXI-2575 196-channels multiplexers and I have a crosstalk issue. Part Number: 184583F-02 When I start running the test bench application, the application starts but there is no communication between the PC (Dell Vostro 220 Mini Tower Desktop) and the PXI-1010 chassis (via 2 cards 8335 MXI-3). The offline version of the NI-DAQmx Help is located at C:UsersPublicDocumentsNational InstrumentsNI-DAQDocumentation. 1 Reply 1591 Views 0 Kudos. •Review <National Instruments>\_Legal Information. You can request repair, RMA, schedule calibration, or get technical support. NI is now part of Emerson. demultiplexers) to deliver a pulse-signal on the COM-port (pin 173) consecutively to the other channels for calibration of some boards. The PXI-8185 includes an integrated hard-drive and USB 1. If more bandwidth is needed, consider upgrading to PXIe. Find many great new & used options and get the best deals for Ni Pxi-8335 Pci-8335 5m Optical Cable Isolated Mxi-3 National Instruments at the best online prices at eBay! Free shipping for many products!National Instruments PXI compact pci chassis, controller and cards: PXI-1006 18 position chassis, PXI-8186 embedded controller, PXI-6608 system timing, PXI-6025E multifunction I/O, PXI-GPIB interface and PXI-8335 isolated communication module. length }}) Equipment Listings . NI’s PXI remote control solutions offer the performance and benefits of t he PXI platform while enabling chassis control through desktop PCs, rackmount controllers, laptops, or. Find many great new & used options and get the best deals for NATIONAL INSTRUMENTS PXI-1045 CHASSIS & PXI-8186 CONTROLLER & PXI-8335 MXI-3 at the best online prices at eBay! Free shipping for many products!Find many great new & used options and get the best deals for National Instruments NI PXI-8335 NI MXI-3 Interf Card, Fiber-Optic 184583F-02 at the best online prices at eBay! Free delivery for many products. Dynamic: The routes are left. We want to keep the digitizers (one PXI-5122 per Chassis) galvanically seperated due to the requirements of our measurement! The chassis are connected using the fiber optic cable. 49. are not included with this equipment unless. Show More Description. Tip Using an NI-DAQmx simulated device, you can test NI-DAQmx applications without. Toggle navigation. NI is now part of Emerson. You can find the. Type: MXI-3 Interface Card. This module can be utilized to connect numerous PXI chassis in a daisy-chain or star arrangement in one system. All prices are shown in USD. Ł Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories. PXI-6713. 2. National Instruments MXI-3 Interface Cable Fiber-Optic (5 Meters) This cable is also labeled: PCI-8335 / PXI-8335. It is used for processor-intensive, modular instrumentation, and data acquisition applications. QUALITY: ABOUT: CONTACT MFG NSN. For PCI-8335, the PWR and TX (nor sure it's TX or RX, j. com provides all kinds of other networking & communications under &price;. Any action against National Instruments must be brought within one year after the cause of action accrues. The software is Labview 2010 sp1 and the NIScope 380 drivers. It couples two physically isolate buses with either a copper or fiber-optic cable equipped for 1. National Instruments»Vision»Documentation»NI-IMAQ. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. 2. 0 andHi, I have a PCI-8335 card in a Dell Optiplex 780. Learn more about PXI, which is a high-performance deployment platform for applications such as manufacturing test, military and aerospace, machine monitoring, automotive, and industrial test. PXI PCI 8330 National Instruments. 27 + $29. I am using them as switch-modules (aka. National Instruments PCI-8335 MXI-3 Interface Board. 엔지니어는 NI PXI를 사용하여 검증과 생산 테스트를. Plug in your chassis before installing the PXI-8840. • EULAs are located in the <National Instruments>SharedMDFLegallicense directory. Picture 1 of 5. 1701, 10/20/2015). 99. txt for information on including legal information in. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. Figure 3-2. Contact us now. Summary of Contents for National Instruments NI 6612. With the NI PXI-5122 100 MS/s 14-bit digitizer, the channel-to-channel jitter is typically under 10 psrms. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents. used. The Triggers tab in MAX allows users to route triggers across buses. Review <National Instruments>\_Legal Information. They offer various configurations and features, such as high current, high voltage, and high density. Note NI-DMM version 2. com, the National Instruments corporate logo, and the Eagle logo are NI’s PXI remote control solutions offer the performance and benefits of t he PXI platform while enabling chassis control through desktop PCs, rackmount controllers, laptops, or other PXI systems. The skew is. I have DAQ Drivers release 7. National Instruments PCI-8335 MXI-3 Interface Module. 09 shipping. In addition to the communication buses, the electrical specification also defines the timing and synchronization capabilities. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。 The 8335 will not show up as a device itself and does not require a driver for base functionality. Provides support for NI data acquisition and signal conditioning devices. Est. Open a service request. Chassis 2. National Instruments PXI-8335 User Manual (31 pages) Figure 2-1. Improved Architecture Compatible with NI 6533. Toggle navigation ({{ cartItems. Allow for the operating system to identify the USB flash disk properly. NI National Instruments PXI-6527 Isolated Digital I/O B * £95. Email: PCI-8335 National Instruments PCI-8335 MXI-3 Interface Module from National Instruments | Buy Today from Artisan. Provides support for NI data acquisition and signal conditioning devices. FOR SALE! Tested in a system, fully functional, and in excellent physical condition. PXI Products, Created by the PXI Leader. • Both the 82577 and 82574 Gigabit Enet ports connect to either 10 Mbit, 100 Mbit, or 1,000 Mbit Ethernet. 0 R 3. It needs to be paired with a PCI 8330 in your desktop computer with a MXI cable running between the two. These kits bridge the PCI bus of your PXI system or external computer to the VXIbus of your test. Manufacturer: National Instruments Model: PXI-8335 PXI-8335, Fiber-optic Cable, MXI-3 Interface Module National Instruments PXI-8335 Interface ModuleThe National Instruments PXI-8335 (Part Number: 777947-01) is an Interface Module with MXI-3 technology. When the desktop PC or the CompactPCI/PXI controller powers on, the system BIOS scans its local PCI bus for devices. MXI-3 Block Diagram. NI EU DoC rev 3 Declaration of Conformity According to EN ISO/IEC 17050-1:2010 Manufacturer Name: National Instruments Address: 11500 North MoPac Expressway. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Work with our experts to sustain your critical applications. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Click to Contact Seller. Note PCI V (I/O) pins in Hybrid Peripheral Slots are connected to +5 V. com today. Best offer accepted. Also for: Pci 8330 series, Pci-8335, Pxi 8330 series. Part Number: 186943B-02, 186943C-02 View Photo of the Heatsink Configuration. Whenever I start s. 2Ghz Pentium 4. Trigger route types are dynamic (the default), Away from Bus 1, Away from Bus 2, and Away from Bus 3. National Instruments does not carry MXI-3 cards. This article discusses compatibility between a MXI-Express card and MXI-4 or MXI-3 connections in older PXI chassis or hosts. Members of the National Instruments Alliance Partner Prog ram are business entities independent from National Instruments and have no agency, partnership, or joint-venture relationship with National Instruments. View a Representative Photo of the Heatsink Configuration. NI is continually pushing the boundaries of performance with its PXI modular instruments, all in a more efficient 3U space. Email: [email protected] • Quick Quotes: Receive Price & Availability Today!PXIe-8135 User Manual. It has the optical fiber interface (not copper). are not included with this equipment unless listed in the above stock item description. 0 GHz Pentium M 760 Embedded Controller for PXI. If you cannot find EtherCAT selection, you need to check your. The module is designed to comply with the following electrical safety standards: IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1. Power on the computer and install the compatible version of PXI Platform Services. Important Notice: Other accessories, manuals, cables, calibration. 2. NI 4080/4081/4082 is a digital multimeter that ships with NI-DMM, which you use to program the device. The additional experimentation on our test system also suggests that our second issue (failures in established links) is not a power supply issue and only indirectly a cable issue. Refer to the chassis documentation for details. See all Driver Software Downloads. 0. National Instruments PXI-8335 MXI-3 Fiber Optic Interface Module CompactPCI Vendu Voir des articles similaires EUR 22,24 Achat immédiat ou Offre directe , 30-Jour Retours, Garantie client eBay Vendeur: valuetronics_international ️ (2. Keysight / Agilent / HP N6033A. Manufacturer:. The PXI‑8366 is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCIe‑8375. PXI-7831R Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 2. (PXI-2565 - PXI-6509 - PXI-6512- ecc. In add. PXI-8335. NI-VISA. com | NI PXIe-4353 and TC-4353 Note When installing NI application software, such as NI LabVIEW, refer to the NI-DAQmx Readme on the software disc for supported software versions. Part Number: 184583F-02. The interface kits are available with Þber-optic (8345) or. AMD shows Win 10-x64 support for this embedded chipset with their AMD Catalyst Windows® 32/64-bit Display Driver release (15. Brand: National Instruments. Basic MXI-3 Configurations. Part Number: 184583F-02 . National Instruments PCI-8335 MXI-3 Interface ModuleIt ships with standard accessories in the National Instruments box. used. Out-of-the-Box Performance of NI-TClk Synchronization of Two 100 MS/s Digitizers. The Acqiris MXI-3 / PXI 8335 Interface Module is a PCI-PCI bridge that needs no software for normal operation. Embedded controllers contain everything you need to run your PXI. . In this case I suspect that one of the 8335 boards (or cable) is broken. MXI-3 utilizes information lines to store information for transmission and furthermore utilizes line information to store information received while waiting for access to the goal. DC Output. These devices offer increased speed, accuracy, and synchronization features that are well suited for high-density sensor measurement and signal-conditioning systems. 1” on my workstation. com today. Make sure the NI-Industrial Communications for EtherCAT driver has been well installed in PXI RT controller. NI PXI Platform Services is already included as part of NI instrument drivers, but there may be cases where. When I insert card into slot, turn on power, the card has amber led link. item 3 ^^ NATIONAL INSTRUMENTS NI. • 122004039352ni-daqmx. I am using them as switch-modules (aka. National Instruments PXI-8335 ; National Instruments PXIe-5832 ; National Instruments PXIe-5114. Phone: (217) 352-9330. I have implemented a MXI-3 interface (PXI-PCI8335) in my XP machine and it works fine with a PXI-1000 crate equipped with different CompactPCI and PXI boards from different manufacturers. My workstation has WIN 7 64 bits OS with current PCI-8335 card installed. Ensure that you have the boards powered on in the correct order (PXI then PCI). Kit includes: 186943B-03: CCA PCI-8330 Fast Reset Card 186897D-01: CCA PXI-8330 Card 1324640-4 0332: 1. National Instruments PXI-8335 MXI-3 Interface Module This unit has the optical fiber interface (not copper). The PXIe-8399 features additional ports and modular cabling for daisy-chaining. Add to Wish List Add to Compare. PXI-1033 This document includes specifications for the PXI-1033 chassis. Related Products. This unit has the copper cable interface (not optical). Your Part No: Enter your custom part number in the textbox aboveor PXI module (PXI-833x), one VXI-834x single-port Slot 0 module, a flexible MXI-3 cable, and NI-VXI/NI-VISA bus interface software. Picture 1 of 2. Somehow, I believe the windows does not recognize my 8335 card. The PXI-PCI 8330 Series incorporates MXI-3 technology. In NI Max, configure the PXI controller Ethernet Adapter eth1 as "EtherCAT" Adapter mode. Installing the PCI MXI-3. Manufacturer Part No: 779503-03. Refer to the PXI. Also for: Pci 8330 series, Pci-8335, Pxi 8330 series. 80 postage.